Skip to Content
Merck
All Photos(1)

Documents

PHR1724

Supelco

Haloperidol

Pharmaceutical Secondary Standard; Certified Reference Material

Synonym(s):

Haloperidol, 4-[4-(4-Chlorophenyl)-4-hydroxy-1-piperidinyl]-1-(4-fluorophenyl)-1-butanone, 4-[4-(4-Chlorophenyl)-4-hydroxypiperidino]-4′-fluorobutyrophenone, 4-[4-(p-Chlorophenyl)-4-hydroxypiperidino]-4′-fluorobutyrophenone

Sign Into View Organizational & Contract Pricing


About This Item

Empirical Formula (Hill Notation):
C21H23ClFNO2
CAS Number:
Molecular Weight:
375.86
EC Number:
MDL number:
UNSPSC Code:
41116107
PubChem Substance ID:
NACRES:
NA.24

grade

certified reference material
pharmaceutical secondary standard

Quality Level

Agency

traceable to BP 407
traceable to Ph. Eur. H0100000
traceable to USP 1303002

API family

haloperidol

CofA

current certificate can be downloaded

packaging

pkg of 400 mg

technique(s)

HPLC: suitable
gas chromatography (GC): suitable

application(s)

pharmaceutical (small molecule)

format

neat

storage temp.

2-30°C

SMILES string

OC1(CCN(CCCC(=O)c2ccc(F)cc2)CC1)c3ccc(Cl)cc3

InChI

1S/C21H23ClFNO2/c22-18-7-5-17(6-8-18)21(26)11-14-24(15-12-21)13-1-2-20(25)16-3-9-19(23)10-4-16/h3-10,26H,1-2,11-15H2

InChI key

LNEPOXFFQSENCJ-UHFFFAOYSA-N

Gene Information

human ... HTR2A(3356)

Looking for similar products? Visit Product Comparison Guide

General description

Pharmaceutical secondary standards for application in quality control, provide pharma laboratories and manufacturers with a convenient and cost-effective alternative to the preparation of in-house working standards.
Haloperidol is a major tranquilizer that is indicated for the treatment of schizophrenia, mania and neurological disorders including hyperkinesia.

Application

Haloperidol may be used as a pharmaceutical reference standard for the determination of the analyte in pharmaceutical formulations by high performance liquid chromatography (HPLC) and spectrophotometry techniques.
These Secondary Standards are qualified as Certified Reference Materials. These are suitable for use in several analytical applications including but not limited to pharma release testing, pharma method development for qualitative and quantitative analyses, food and beverage quality control testing, and other calibration requirements.

Analysis Note

These secondary standards offer multi-traceability to the USP, EP and BP primary standards, where they are available.

Other Notes

This Certified Reference Material (CRM) is produced and certified in accordance with ISO 17034 and ISO/IEC 17025. All information regarding the use of this CRM can be found on the certificate of analysis.

Footnote

To see an example of a Certificate of Analysis for this material enter LRAB7792 in the Documents slot below. This is an example certificate only and may not be the lot that you receive.

Recommended products

Find a digital Reference Material for this product available on our online platform ChemisTwin® for NMR. You can use this digital equivalent on ChemisTwin® for your sample identity confirmation and compound quantification (with digital external standard). An NMR spectrum of this substance can be viewed and an online comparison against your sample can be performed with a few mouseclicks. Learn more here and start your free trial.

Pictograms

Skull and crossbonesHealth hazard

Signal Word

Danger

Hazard Classifications

Acute Tox. 3 Oral - Eye Irrit. 2 - Repr. 2 - Skin Irrit. 2 - Skin Sens. 1 - STOT SE 3

Target Organs

Respiratory system

WGK

WGK 3

Flash Point(F)

Not applicable

Flash Point(C)

Not applicable


Choose from one of the most recent versions:

Certificates of Analysis (COA)

Lot/Batch Number

Don't see the Right Version?

If you require a particular version, you can look up a specific certificate by the Lot or Batch number.

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library

Customers Also Viewed

Slide 1 of 5

1 of 5

Haloperidol solution 1.0 mg/mL in methanol, ampule of 1 mL, certified reference material, Cerilliant®

Supelco

H-030

Haloperidol solution

Carbamazepine Pharmaceutical Secondary Standard; Certified Reference Material

Supelco

PHR1067

Carbamazepine

Risperidone ≥98% (HPLC), powder

Sigma-Aldrich

R3030

Risperidone

Fluconazole Pharmaceutical Secondary Standard; Certified Reference Material

Supelco

PHR1160

Fluconazole

Omeprazole Pharmaceutical Secondary Standard; Certified Reference Material

Supelco

PHR1059

Omeprazole

Quantitative high performance liquid chromatographic determination of bamipine combined with tricyclic antidepressants and/or antipsychotics in pharmaceutical formulations.
Kountourellis JE, et al.
Analytical Letters, 26(10), 2171-2182 (1993)
Validation of derivative spectrophotometry method for determination of active ingredients from neuroleptics in pharmaceutical preparations.
Stolarczyk M, et al.
Acta Poloniae Pharmaceutica, 66(4), 351-356 (2009)
Determination and degradation study of haloperidol by high performance liquid chromatography.
Trabelsi H, et al.
Journal of Pharmaceutical and Biomedical Analysis, 29(4), 649-657 (2002)

Articles

Analysis of 20 pharmaceutical compounds in calf serum using Supel™ Swift HLB SPE cartridge for cleanup and LC-MS determination and another commercially available HLB cartridge for comparison.

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service