Direkt zum Inhalt
Merck

P3B050A05

Millipore

Pellicon® 3-Kassette mit Biomax® Membran

50kDa, A Screen, 0.57 m2

Synonym(e):

Pellicon® 3 Cassette with Biomax 50 kDa Membrane, A screen, 0.57 m2

Anmeldenzur Ansicht organisationsspezifischer und vertraglich vereinbarter Preise


About This Item

UNSPSC-Code:
23151806
eCl@ss:
32031623

Materialien

TPE seal
polyethersulfone
polypropylene screen
stainless steel cap (for end; polypropylene-encapsulated)

Qualitätsniveau

Leistungsmerkmale

holdup volume 69 mL (in feed channel)

Hersteller/Markenname

Pellicon®

Parameter

30 psi max. reverse press. exposure at 25 °C (for 24 hours)
4-6 L/min-m2 recirculation rate
40 psi max. transmembrane pressure at 4-50 °C
6.9 bar max. inlet pressure (100 psi)
80 psi max. transmembrane pressure at 4-40 °C

Methode(n)

analytical sample preparation: suitable
buffer exchange: suitable
protein purification: suitable (concentration)

Höhe

2.4 cm (0.93 in.)

Länge

20.6 cm (8.1 in.)

Breite

17.8 cm (7 in.)

Membranfläche

0.57 m2

Gravimetrisch bestimmte extrahierbare Substanzen

≤1500 mg/m2

Matrix

Biomax® (Membrane)

Porengröße

50 kDa NMWCO

pH-Wert

1-14

Suchen Sie nach ähnlichen Produkten? Aufrufen Leitfaden zum Produktvergleich

Allgemeine Beschreibung

Pellicon® 3 filtration devices are advanced, high-performance cassettes ideal for today’s higher titer therapeutic antibodies as well as the more demanding filtration processes that require higher operating pressures, temperatures and caustic cleaning regimes.

The Pellicon® 3 Cassette with Biomax® Membrane is perfect for the filtration of monoclonal antibodies and solutions containing albumin, hormones, vaccines and growth factors.

This P3B050A05 Pellicon® 3 ultrafiltration device features a pore size of 50 kDa NMWCO, a Biomax® 50 membrane, and dimensions measuring 2.4 cm (H) x 17.8 cm (W) x 20.6 cm (L).

Leistungsmerkmale und Vorteile

  • Rugged & reliable – ideally suited for today′s more demanding filtration processes
  • High performance – produces excellent resolution, yields and back-pressure resistance
  • Optimum product recovery – thanks to proven membrane technology
  • Void-free technology – leading-edge membranes resolve virtually any separation challenge
  • Defect-free, superior adhesion – Ultracel®uses composite membranes cast on a microporous substrate
  • Automated manufacturing – delivers unbeatable performance, consistency and reliability
  • Easy installation & care – simple to install and maintain

Sonstige Hinweise

These products are manufactured in a facility which adheres to Good Manufacturing Practices.

Hinweis zur Analyse

Gravimetric Extractables: after 24 hours in water at controlled room temperature

Rechtliche Hinweise

BIOMAX is a registered trademark of Merck KGaA, Darmstadt, Germany
Pellicon is a registered trademark of Merck KGaA, Darmstadt, Germany
ULTRACEL is a registered trademark of Merck KGaA, Darmstadt, Germany

Lagerklassenschlüssel

8B - Non-combustible, corrosive hazardous materials

WGK

WGK 1


Analysenzertifikate (COA)

Suchen Sie nach Analysenzertifikate (COA), indem Sie die Lot-/Chargennummer des Produkts eingeben. Lot- und Chargennummern sind auf dem Produktetikett hinter den Wörtern ‘Lot’ oder ‘Batch’ (Lot oder Charge) zu finden.

Besitzen Sie dieses Produkt bereits?

In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.

Die Dokumentenbibliothek aufrufen

Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..

Setzen Sie sich mit dem technischen Dienst in Verbindung.