V-010
(±)-α-Tocopherol-D6 (Vitamin E-D6) solution
500 μg/mL in methanol, ampule of 1 mL, certified reference material, Cerilliant®
About This Item
Empfohlene Produkte
Qualität
certified reference material
Qualitätsniveau
Form
liquid
Leistungsmerkmale
(Snap-N-Spike®
Snap-N-Shoot®)
Verpackung
ampule of 1 mL
Hersteller/Markenname
Cerilliant®
Konzentration
500 μg/mL in methanol
Methode(n)
gas chromatography (GC): suitable
liquid chromatography (LC): suitable
mp (Schmelzpunkt)
-97.99 °C
Anwendung(en)
clinical testing
clinical testing
Format
single component solution
Lagertemp.
−20°C
Allgemeine Beschreibung
Anwendung
The certified reference material (CRM) in solution can also be used as an internal standard as follows:
- High-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) based combined analysis of retinol, α‐tocopherol, 25‐hydroxyvitamin D2, and 25‐hydroxyvitamin in plasma samples of cardiovascular patients
- Simultaneous determination of 25-hydroxyvitamin-D2 (25-OHD2), 25-hydroxyvitamin-D3 (25-OHD3), and its 3-epimer (epi-25-OHD3), retinol, and α-tocopherol in human serum samples by liquid chromatography-tandem mass spectrometry (LC-MS/MS)
- Development of two ultra and high-performance liquid chromatographic methods, one coupled with atmospheric pressure chemical ionization and tandem mass spectrometric detector (UHPLC-APCI-MS/MS) and the other one with diode array detector (HPLC-DAD) to estimate fat-soluble vitamins A, D3 and E in rice cereal-based baby food samples
- Multi-residue analysis of fat-soluble vitamins (FSVs)― retinol, 25(OH)D2, 25(OH)D3, epi-25(OH)D3. and α-tocopherol in plasma and amniotic fluid samples by liquid chromatography-tandem mass spectrometry (LC-MS/MS) following a single pre-treatment step
Leistungsmerkmale und Vorteile
- Fully characterized under ISO/IEC 17025 and ISO 17034 accreditation
- Accompanied with a comprehensive Certificate of Analysis (CoA) with data on stability, homogeneity, accuracy of concentration, uncertainty, and traceability
- Rigorously tested through real-time stability studies to ensure accuracy and shelf life
- Gravimetrically prepared using qualified precision balances to ensure minimal uncertainty
- Flame sealed under argon into ampoules for long-term shelf life
- Offered in a convenient, DEA-exempt format to improve laboratory efficiency
Rechtliche Hinweise
Ähnliches Produkt
Signalwort
Danger
Gefahreneinstufungen
Acute Tox. 3 Dermal - Acute Tox. 3 Inhalation - Acute Tox. 3 Oral - Flam. Liq. 2 - STOT SE 1
Zielorgane
Eyes
Lagerklassenschlüssel
3 - Flammable liquids
WGK
WGK 2
Flammpunkt (°F)
49.5 °F - closed cup
Flammpunkt (°C)
9.7 °C - closed cup
Zulassungslistungen
Zulassungslistungen werden hauptsächlich für chemische Produkte erstellt. Für nicht-chemische Produkte können hier nur begrenzte Angaben gemacht werden. Kein Eintrag bedeutet, dass keine der Komponenten gelistet ist. Es liegt in der Verantwortung des Benutzers, die sichere und legale Verwendung des Produkts zu gewährleisten.
EU REACH Annex XVII (Restriction List)
Analysenzertifikate (COA)
Suchen Sie nach Analysenzertifikate (COA), indem Sie die Lot-/Chargennummer des Produkts eingeben. Lot- und Chargennummern sind auf dem Produktetikett hinter den Wörtern ‘Lot’ oder ‘Batch’ (Lot oder Charge) zu finden.
Besitzen Sie dieses Produkt bereits?
In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.
Kunden haben sich ebenfalls angesehen
Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..
Setzen Sie sich mit dem technischen Dienst in Verbindung.